Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. esp. quimioter ; 37(1): 88-92, Feb. 2024. tab
Artigo em Inglês | IBECS | ID: ibc-230426

RESUMO

The new automated systems designed for rapid performance of AST have significantly reduced the response time for susceptibility testing of microorganisms causing bacteremia and sepsis. The Accelerate Pheno® system (AAC) is one such system. Our objective for this study was to determine whether the AAC system is capable of providing an accurate susceptibility profile to infer resistance mechanisms in different carbapenemase-producing isolates when compared to the MicroScan WalkAway System (MWS). Disk diffusion method was also performed on all isolates as a reference method. Additionally, we compared the results obtained with the routine AST production system. We selected 19 isolates from the cryobank of the Microbiology department, all of which were carbapenemase-producing gram-negative bacilli. AAC was able to identify and infer the resistance of a total of 10 isolates, with an EA and CA of 84.2% for meropenem and 88.2% and 64.7% for ertapenem EA and CA, respectively. If we consider the disk diffusion technique, the CA was 57.9% and 76.5% for meropenem and ertapenem. However, in the presence of carbapenemases, AAC was not able to provide adequate MICs or infer the resistance mechanisms of the isolates accurately. Further studies with a larger number of isolates, including the new antibiotics ceftolozane/tazobactam and ceftazidime/avibactam, are needed for a more comprehensive comparison. (AU)


Los nuevos sistemas automatizados diseñados para la realización rápida de antibiogramas han reducido significativamente el tiempo de respuesta para las pruebas de susceptibilidad de los microorganismos causantes de bacteriemia y sepsis. El sistema Accelerate Pheno® (AAC) es uno de ellos. Nuestro objetivo para este estudio era determinar si el sistema AAC es capaz de proporcionar un perfil de sensibilidad preciso para inferir mecanismos de resistencia en diferentes aislados productores de carbapenemasas en comparación con el sistema MicroScan WalkAway (MWS). El método de disco difusión fue incluido también en todos los aislados como método de referencia. Además, comparamos los resultados obtenidos con el sistema rutinario de producción de antibiogramas rápidos. Seleccionamos 19 aislados del criobanco del departamento de Microbiología, todos ellos bacilos gramnegativos productores de carbapenemasas. AAC fue capaz de identificar e inferir la resistencia de un total de 10 aislados, con una EA y CA del 84,2% para el meropenem y del 88,2% y 64,7% para la EA y CA del ertapenem, respectivamente. Si consideramos la técnica de disco difusión, la CA fue de un 57.9% y de un 76.5% para meropenem y ertapenem. Sin embargo, en presencia de carbapenemasas, AAC no fue capaz de proporcionar CMIs adecuadas ni de inferir con precisión los mecanismos de resistencia de los aislados. Se necesitan más estudios con un mayor número de aislados incluyendo también los nuevos antibióticos ceftolozano/tazobactam y ceftazidima/avibactam para una comparación más exhaustiva. (AU)


Assuntos
Humanos , Anti-Infecciosos/uso terapêutico , /métodos , Antibacterianos/farmacologia , Resistência a Medicamentos , Resistência Microbiana a Medicamentos , Ertapenem , Bactérias Gram-Negativas , Testes de Sensibilidade Microbiana
2.
J Microbiol Methods ; 211: 106789, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37479088

RESUMO

The objective of the study was to compare the diagnostic performances of three Bruker MALDI-TOF MS target plates. A combination of two or three targets results in an increase of the identification percentage, especially in problem isolates as gram-positive cocci and yeast.


Assuntos
Hemocultura , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
3.
Rev. esp. quimioter ; 35(3): 284-287, jun.-jul. 2022. tab
Artigo em Inglês | IBECS | ID: ibc-205371

RESUMO

Background. Bloodstream infections (BSI) caused by extended-spectrum beta-lactamases Enterobacteriaceae (ESBL-E) are associated with high rates of treatment failure andincreased mortality, especially when appropriate antimicrobialtherapy is delayed. Our aim was to evaluate the anticipationof ESBLs detection and the potential improvement of the timeresponse of the Vitek 2 System (BioMérieux; France).Methods. We compared this lateral flow immunoassaywhen used directly on fluid from positive blood cultures to theVITEK2 AST system. We evaluated 80 isolates, 61 tested directlyon fluid from positive blood cultures and 19 tested on fluidfrom blood cultures spiked with known ESBL positive and negative organisms.Results. The concordance between the CTX-LFIA and thereference method (Vitek 2) had a Cohen´s Kappa coefficient of0.97, indicating a particularly good correlation between bothcompared methods.Conclusion. This lateral flow immunoassay can be morerapid than the Vitek 2 for earlier presumptive identification ofCTX- M ESBLs and can be useful to anticipate results and theadjustment of antimicrobial therapy. (AU)


Antecedentes. Las bacteriemias causadas por Enterobacteriaceae productoras beta-lactamasas de espectro extendido(BLEE) están asociadas con altas tasas de fallo de tratamientoy mortalidad, especialmente cuando se retrasa el tratamientoapropiado. Nuestro objetivo ha sido evaluar la anticipación dela detección de estas BLEE y la potencial mejora en el tiempode respuesta respecto al VITEK2 System (Biomerieux; Francia).Métodos. Se comparó una inmunocromatografía para sudetección con el VITEK2 AST system directamente del hemocultivo. Se evaluaton 80 aislados, 61 evaluados directamentede hemocultivos positivos y 19 de la misma manera pero inoculados con microorganismos productores y no productores deBLEE.Resultados. La concordancia entre la inmunocromatografía y el VITEK2 AST mostró un coeficiente Kappa de 0,97,indicando una buena correlación entre ambas técnicas.Conclusión. Esta inmunocromatografía puede ser másrápida que el VITEK2 para una identificación de BLEE tipo CTXM y puede ser útil para anticipar resultados y ajustar la terapiaantimicrobiana. (AU)


Assuntos
Humanos , Cromatografia de Afinidade , beta-Lactamases , Mortalidade , Tratamento Farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...